  Datasheet File OCR Text:
 TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Measurement condition
Ambient temperature: 23 C Input power level: 0 dBm Terminating impedance's : 50
Filter Specification
TFS 125K
1/5
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 125K is the maximum attenuation in the pass band. The maximum attenuation in the pass band is defined as the insertion loss a e. The nominal frequency fN is fixed at 125 MHz without tolerance or limit. The values of relative attenuation a rel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss (Reference level) Nominal frequency 1 dB band width Pass band ripple within Relative attenuation fN fN 14 fN 28 fN + 14 fN + 23 fN + 33 VSWR fN - 150 MHz... fN MHz... fN MHz... fN + MHz... fN + MHz... fN + kHz ... fN + fN
BW ae
typ. value
1,88 dB
tolerance / limit
2,5 1,0 dB
2,80 0,10 MHz dB max.
125 300
MHz kHz
100KHz
arel
0,20 dB
150 kHz 28 124 23 33 325 MHz MHz MHz MHz MHz
50 65 40 55 42 1.3:1 dB dB dB dB dB
max. min. min. min. min. min. max
1 5 12 30 44 38 2:1
dB dB dB dB dB dB
150 kHz
GD*)
Absolute group delay fN 150 kHz ... fN +
150 kHz
GDR *)
245
ns
max. 300
ns
Group delay ripple fN 150 kHz ... fN +
150 kHz **)
15
ns
max. 100
ns
Intermodulation IP3 Input power level
54
TCf ***)
dB ppm/K
min. max
45 10 -
dB dBm
Temperature coefficient of frequency Operating temperature range Storage temperature range
- 72 -
- 10 C ... + 85 C - 30C ... + 85 C
*) measured with smoothing; smoothing aperture 50 kHz **) modulation signals: fN and fN + 14 MHz, each of 10 dBm; measured signal: ***) f(Hz) = TCf(ppm/K) x ( T) x fTo(MHz)
fN - 14 MHz
generated: checked / approved:
TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Construction and pin connection
(All dimensions in mm)
Filter Specification
TFS 125K
2/5
9,3 Max. 8 7 6 9 10 1 2 3
TFS125K
5 4
Date code
1 2 3 4 5 6 7 8 9 10
Ground Ground Ground Ground Output Ground Ground Ground Ground Input
2,54 0,12,54 0,1 0,10 2 3 1 10 9 8 7 0,8 7,1 6 4 5
Date code: Year+week
N P R ...
2001 2002 2003
TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Stability Characteristics
Filter Specification
TFS 125K
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W Po Do E F P2 P1 Ao Bo CT
: : : : : : : : : :
16 4
0,3 0,1
Do Po P2
1,5 + 0,1 1,75 0,1 7,5 0,1 0,6 2 8 1,5 5,3 9,7 0,1 0,1
COVER TAPE P1 CT Ao F W D1 E
G (min) :
0,1 0,1
Bo
G
D1(min) :
13,5 + 0,1
W2
Reel (all dimensions in mm): A W1 N (min) C : : : : 330 16,4 +2 22,4 50
C
W2 (max) :
13
+ 0,5 / - 0,2
A N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 125K
4/5
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
History
Version 1.0 Reason of Changes
Filter Specification
TFS 125K
5/5
Name
Date
- generation of development specification according to the customer specification (V-1.0.0; 15 Jan 03) - add of typical values and generation of filter specification - updated of filter specification according to customer specification, version 2.0.0
Dr. Sabah Dr. Sabah Dr. Sabah
07.03.03 03.06.03 17.06.03
1.1 1.2
TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS125K

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X